Performance Standard: DL/T1059-2007
Heat shrinkable tube on bus bar can be used in HV/LV circuit breaker-cabinet in power plant & substation for bus bar protective/insulation material against short circuit due to small animal creeping to energized bus bar. Protective for human being touching the energized parts. anti-pollution & condensate caused flash over. At the same time it can reduce the distance between phases and phases to ground and prolong the age of use.
Features.-
-
Material: cross-linked polyolefin.
-
Operating temperature: -45 oC ~ 105 oC.
-
Shrink temperature: start at 100 oC and shrink totally at 130 oC.
-
Color: Red, green, yellow, blue, black.
Product Dimensions (10 kV Heat shrinkable tube on bus bar)
|
Order Ref. No. |
As supplied |
After recovery |
Suitable for Rectangular Busbar (mm) |
Suitable for Circular Busbar (mm) |
ID |
Wall Thickness |
ID |
Wall Thickness |
Ø 20 |
≥ 20 |
1.2 |
≤ 8 |
2.5 ± 0.1 |
20 |
15 |
Ø 25 |
≥ 25 |
1.2 |
≤ 11 |
2.5 ± 0.1 |
25 |
15 |
Ø 30 |
≥ 30 |
1.2 |
≤ 13 |
2.5 ± 0.1 |
30 |
20 |
Ø 40 |
≥ 40 |
1.2 |
≤ 16 |
2.5 ± 0.1 |
40 |
25 |
Ø 50 |
≥ 50 |
1.3 |
≤ 18 |
2.8 ± 0.1 |
50 |
30 |
Ø 60 |
≥ 60 |
1.3 |
≤ 25 |
2.8 ± 0.1 |
60 |
40 |
Ø 70 |
≥ 70 |
1.3 |
≤ 29 |
2.8 ± 0.1 |
70 |
50 |
Ø 80 |
≥ 80 |
1.3 |
≤ 34 |
2.8 ± 0.1 |
80 |
55 |
Ø 100 |
≥ 100 |
1.3 |
≤ 41 |
2.8 ± 0.1 |
100 |
75 |
Ø 120 |
≥ 120 |
1.3 |
≤ 48 |
2.8 ± 0.1 |
120 |
85 |
Ø 150 |
≥ 150 |
1.3 |
≤ 62 |
2.8 ± 0.1 |
150 |
105 |
Ø 180 |
≥ 180 |
1.3 |
≤ 73 |
2.8 ± 0.1 |
180 |
120 |
Ø 210 |
≥ 210 |
1.3 |
≤ 84 |
2.8 ± 0.1 |
210 |
130 |
Ø 230 |
≥ 230 |
1.2 |
≤ 85 |
2.8 ± 0.1 |
230 |
135 |
Ø 250 |
≥ 250 |
1.5 |
≤ 102 |
3.9 ± 0.2 |
240 |
140 |
Ø 275 |
≥ 275 |
1.4 |
≤ 102 |
3.9 ± 0.2 |
250 |
145 |
Ø 300 |
≥ 300 |
1.6 |
≤ 110 |
3.9 ± 0.2 |
300 |
160 |
Product Dimensions (35 kV Heat shrinkable tube on bus bar)
|
Order Ref. No. |
As supplied |
After recovery |
Suitable for Rectangular Busbar (mm) |
Suitable for Circular Busbar (mm) |
ID |
Wall Thickness |
ID |
Wall Thickness |
Ø 20 |
≥ 20 |
2.0 |
≤ 8 |
4.8 ± 0.2 |
20 |
15 |
Ø 25 |
≥ 25 |
2.0 |
≤ 10 |
4.8 ± 0.2 |
25 |
15 |
Ø 30 |
≥ 30 |
2.0 |
≤ 15 |
4.8 ± 0.2 |
30 |
20 |
Ø 40 |
≥ 40 |
2.0 |
≤ 16 |
4.8 ± 0.2 |
40 |
25 |
Ø 50 |
≥ 50 |
2.0 |
≤ 20 |
5.0 ± 0.2 |
50 |
25 |
Ø 60 |
≥ 60 |
2.0 |
≤ 25 |
5.2 ± 0.2 |
60 |
30 |
Ø 70 |
≥ 70 |
2.0 |
≤ 30 |
5.2 ± 0.2 |
70 |
35 |
Ø 80 |
≥ 80 |
2.0 |
≤ 32 |
5.2 ± 0.2 |
80 |
40 |
Ø 100 |
≥ 100 |
2.0 |
≤ 40 |
5.2 ± 0.2 |
100 |
75 |
Ø 120 |
≥ 120 |
2.0 |
≤ 50 |
5.2 ± 0.2 |
120 |
85 |
Ø 150 |
≥ 150 |
2.0 |
≤ 60 |
5.2 ± 0.2 |
150 |
105 |
Ø 180 |
≥ 180 |
2.2 |
≤ 70 |
5.6 ± 0.2 |
180 |
120 |
Ø 210 |
≥ 210 |
2.1 |
≤ 80 |
5.8 ± 0.2 |
210 |
130 |
Technical Data
|
Property |
Test Method |
Standard Value |
Operating temperature |
IEC 216 |
-45 oC to +105 oC |
Tensile strength |
ASTM-D 638 |
≥ 13 MPa |
Elongation at break |
ASTM-D 638 |
≥ 300% |
Tensile strength after aging |
ASTM-D 2671/120 oC, 168 hrs |
≥ 11 MPa |
Elongation at break after aging |
ASTM-D 2671/120 oC, 168 hrs |
≥ 220% |
Dielectric Strength |
IEC 243 |
≥ 20 kV/mm |
Tracking resistance |
ASTM-D 2303 |
3.75 Kv, 1h, pass |
Volume resistance |
ASTM-D 2303 |
≥ 1x1014 Ω.cm |
Dielectric constant |
IEC 250 |
3.0 |
Longitudinal shrinkage |
- |
≤ 10% |
Eccentricity |
ASTM-D 267 |
≤ 30% |
Water absorption |
ISO 62 |
≤ 0.1% |
Flammability (Oxygen index) |
IEC 93 |
≥ 28 |
Copper corrosion |
ASTM-D 2671 |
120 oC, 168 hrs, no corrosion |
Cold bend |
ASTM-D 2671 |
-40 oC, 4 hrs, no cracking |
Minimum shrink temperature |
- |
100 oC |
Minimum fully recovered temperature |
- |
130 oC |