The product is mainly used for cable insulation and sealing over the crutch of multi-core cable, there are two core, three core, four core, five-finger of the points. Conductive breakout provide effective conductive screen and sealing protection to the cable termination.
Features.-
-
Shrink ratio accommodates a wide range of cables.
-
Boots for 2, 3, 4 and 5 way cable.
-
Strain relief and mechanical protection.
-
Thermoplastic adhesive liner.
-
Continuous operating temperature: -45 oC ~ 105 oC.
-
Shrink temperature: 135 oC.
Dimensions
|
Order Ref. Number |
Breakout main distance |
Finger diameter |
Full length (mm) |
Finger length (mm) |
As supplied (mm) |
After recovery (mm) |
As supplied (mm) |
After recovery (mm) |
2 cores breakout |
WRSZT2-27/12 |
≥ 27 |
≤ 12 |
≥ 12 |
≤ 6 |
135 ± 5 |
55 ± 5 |
WRSZT2-40/14 |
≥ 40 |
≤ 13 |
≥ 20 |
≤ 8 |
145 ± 5 |
60 ± 5 |
WRSZT2-50/15 |
≥ 50 |
≤ 15 |
≥ 25 |
≤ 10 |
145 ± 5 |
65 ± 5 |
WRSZT2-65/25 |
≥ 65 |
≤ 25 |
≥ 35 |
≤ 12 |
140 ± 5 |
55 ± 5 |
WRSZT2-72/25 |
≥ 72 |
≤ 25 |
≥ 40 |
≤ 12 |
140 ± 5 |
55 ± 5 |
3 cores breakout |
WRSZT3-27/17 |
≥ 27 |
≤17 |
≥ 11 |
≤ 6 |
130 ± 5 |
50 ± 5 |
WRSZT3-50/22 |
≥ 50 |
≤ 22 |
≥ 18 |
≤ 7 |
165 ± 5 |
60 ± 5 |
WRSZT3-60/28 |
≥ 60 |
≤ 28 |
≥ 25 |
≤ 9 |
170 ± 5 |
65 ± 5 |
WRSZT3-70/39 |
≥ 70 |
≤ 39 |
≥ 30 |
≤ 14 |
215 ± 5 |
80 ± 5 |
WRSZT3-85/45 |
≥ 85 |
≤ 45 |
≥ 40 |
≤ 16 |
220 ± 5 |
90 ± 5 |
WRSZT3-105/53 |
≥ 105 |
≤ 53 |
≥ 42 |
≤ 19 |
225 ± 5 |
90 ± 5 |
WRSZT3-125/63 |
≥ 125 |
≤ 63 |
≥ 58 |
≤ 25 |
220 ± 5 |
85 ± 5 |
WRSZT3-140/63 |
≥ 140 |
≤ 63 |
≥ 65 |
≤ 25 |
220 ± 5 |
85 ± 5 |
4 cores breakout |
WRSZT4-40/18 |
≥ 40 |
≤ 18 |
≥ 10 |
≤ 6 |
130 ± 5 |
55 ± 5 |
WRSZT4-50/24 |
≥ 50 |
≤ 24 |
≥ 16 |
≤ 7 |
150 ± 5 |
55 ± 5 |
WRSZT4-70/32 |
≥ 70 |
≤ 32 |
≥ 25 |
≤ 10 |
175 ± 5 |
75 ± 5 |
WRSZT4-80/44 |
≥ 80 |
≤ 44 |
≥ 30 |
v 13 |
215 ± 5 |
60 ± 5 |
WRSZT4-90/44 |
≥ 90 |
≤ 44 |
≥ 35 |
≤ 13 |
215 ± 5 |
60 ± 5 |
WRSZT4-110/51 |
≥ 110 |
≤ 51 |
≥ 40 |
≤ 17 |
225 ± 5 |
55 ± 5 |
5 cores breakout |
WRSZT5-45/21 |
≥ 45 |
≤ 21 |
≥ 12 |
≤ 5 |
150 ± 5 |
55 ± 5 |
WRSZT5-55/29 |
≥ 55 |
≤ 29 |
≥ 16 |
≤ 8 |
170 ± 5 |
65 ± 5 |
WRSZT5-70/38 |
≥ 70 |
≤ 38 |
≥ 25 |
≤ 10 |
175 ± 5 |
65 ± 5 |
WRSZT5-90/49 |
≥ 90 |
≤ 49 |
≥ 30 |
≤ 13 |
185 ± 5 |
80 ± 5 |
WRSZT5-120/49 |
≥ 120 |
≤ 49 |
≥ 39 |
≤14 |
190 ± 5 |
80 ± 5 |
Technical Data
|
Property |
Test Method |
Standard Value |
Insulated breakout |
Oil resistant breakout |
Conductive breakout |
Operating temperature |
IEC 216 |
-55 oC ~ 100 oC |
-20 oC ~ 100 oC |
-55 oC ~ 100 oC |
Tensile strength |
ASTM D 2671 |
≥ 13 MPa |
≥ 12 MPa |
≥ 12 MPa |
Elongation |
ASTM D 2671 |
≥ 300% |
≥ 300% |
≥ 300% |
Tensile strength after thermal aging |
ASTM D 2671 130oC/168 hrs |
≥ 11 MPa |
≥ 10 MPa |
≥ 10 MPa |
Elongation at break after thermal aging |
ASTM D 2671 130oC/168 hrs |
≥ 230% |
≥ 230% |
≥ 230% |
Water absorption |
ISO 62 |
≤ 0.1% |
≤ 0.1% |
≤ 0.1% |
Volume resistance |
IEC 93 |
≥ 1x1014 Ω.cm |
≥ 1x1014 Ω.cm |
102 ~ 103 Ω.cm |
Oil resistance (tensile strength after dipping) |
ASTM D 2671 70# cable oil/168 hrs |
- |
≥ 10 MPa |
- |
Oil resistance (elongation at break after dipping) |
ASTM D 2671 70# cable oil/168 hrs |
- |
≥ 230% |
- |
Dielectric strength |
IEC 243 |
≥ 20 KV/mm |
≥ 20 KV/mm |
- |
Remark.- Conductive breakout general is three cores breakout
|